Newly added to the information center are the ada codes for computer floors.
Computer floor load rating.
Dead load weight of structure and fixed loads 10 lbs ft 2.
More than the sum of the parts cable management floor is a big part of your building.
2 grade of douglas fir are indicated below.
The weight of the machine plus the full rated load.
Live load reductions are not permitted for specific types see code.
Between psi ratings load bearing capability crush strength rolling tests and more it s hard to know which panel is right for your application.
Occupied floor area the projected contact area of the footprint of the machine.
The load rating of the raised floor will depend on the design and purpose of the room.
Uniform loads psf on apa rated plywood sturd i floor.
If you are unfamiliar with the the terms used to describe the loads on raised floor a quick visit to understanding loads will assist you.
Live load is weight of furniture wind snow and more.
The floor loading should not exceed 240 kg m 2 50 lb ft 2 with a partition allowance of 100 kg m 2 20 lb ft 2 for a total floor load rating of 340 kg m 2 70 lb ft 2.
1 ft 0 3048 m.
The weight of the machine excluding the rated load.
Rated load the maximum platform capacity rating.
If you are new to raised floor terminology we suggest a visit to the glossary.
In other words it refers to the capacity of an access floor system to continue to perform its intended function when supporting a specific amount of weight.
A typical wood frame floor covered with carpet or vinyl flooring has a dead load of about 8 pounds per square foot.
While solid tiles might be able to support the current and near future load requirements the perforated tiles cannot.
Rolling load limits traditionally used in computer rooms and.
Maximum floor joist span for no.
Access floor systems office use computer use armories and drill rooms assembly areas fixed seats fastened to floor lobbies movable seats platforms assembly stage floors assembly areas other 50 2 4.
Gross vehicle weight gvw minimum.
You should know that the rating of an access floor is more than the load rating of its panels.
1 psf lb f ft 2 47 88 n m 2.
Multi span normal duration of load dry conditions panels 24 inches or wider.
The dead load on a floor is determined by the materials used in the floor s construction.
Load capacity refers to the maximum demand stress or load that may be placed on a given raised floor system under normal or otherwise specified conditions for an extended period of time.
The raised floor weight plus the cable weight adds 50 kg m 2 10 lb ft 2 uniformly across the total area used in calculations and is included in the 340 kg m 2 70 lb ft 2.